UV-1800
SHIMADZU UV-VIS SPECTROPHOTOMETER MANUFACTURED
BY SHIMADZU CORPORATION JAPAN.
A compact, double beam UV-VIS spectrophotometer wrapped in a sleek form. The UV-1800 uses the Czerny-Turner mounting for its monochromator, and boasts the highest resolution in its class, a bright optical system and a compact design. Available as either a Stand-alone instrument or a PC-controlled instrument. The UV-1800 is USB-memory ready, which enables users to save measurement date to highly versatile USB memory, and perform data analysis and printing using a PC. Supplied with 1 Pair of 10 mm rect. quartz Cell.
Features:
- BUILT - IN DNA /PROTIEN QUANTITATION SOFTWARE
- Highest resolution it its class - 1 nm
- Space-Saving Design
- Data operability is expanded by the use of USB memory
- The function available with earlier instrument have been improved to give greater operability
- From photometric to protein quantitation modes as a standard feature
- Equipped with a variety of measurement
- Control with UV Probe Software
Specifications:
Wavelength range : 190 to 1100nm
Spectral bandwidth : 1 nm (190 to 1,100nm)
Wavelength display : 0.1 nm increments (1nm increments when setting scanning Range)
Wavelength accuracy : +/- 0.1 nm at D2 peak 656.1nm +/- 0.3 nm for entire range
Wavelength repeatability : +/- 0.1 nm
Wavelength slew rate : About 6000 nm/min
Wavelength scanning speed : 3000 to 2 nm/min Lamp interchangeable
Wavelength : Automatic interchangeable linked to wavelength can be set Freely in the range of 295 to 364 nm(0.1 increment)
Stray light : Less than 0.02% at 220nm (Nal) Less than 0.02% at 340 nm (NaNO2) Less than 1.0% at 198 nm (KCl)
Photometric system : Double beam optics
Photometric range : Absorbance: -4 to 4 Abs,
Transmittance : 0% to 400%
Photometric accuracy : +/- 0.002 Abs at 0.5Abs
+/- 0.004 Abs at 1.0 Abs
+/- 0.006 Abs at 2.0 Abs (measured using NIST 938D/NIST1930
or equivalent)
Photometric repeatability : Less than +/-0.001 Abs at 0.5 Abs
Less than +/- 0.001 Abs at 1 Abs
Less than +/- 0.003 Abs at 2 Abs
Baseline Stability : Less than 0.0003Abs/Hr (700nm 1hour after light source turned
ON)
Baseline flatness : Less than +/-0.0006 Abs (1100 - 190nm 1 hr after light source
Turned ON)
Noise level : Less than 0.00005 Abs (700 nm)
Light source : 20-W halogen lamp and D2 lamp built-in source auto position
Adjustment
Monochromator : Blazed holographic grating Czerny-Turner mounting
Detector : Silicone Photodiode
Sample compartment : Internal dia: 110(W) x250(D) x115(H) mm
Distance between light beams : 100mm
Environmental requirements : Temperature : 15°C to 35°C,
Humidity : 30% to 80%
Dimensions : 450 (W) x490(D) x270(H) mm
Weight : 15 kg.
Output device : USB memory (optional) Data files saved in text format or UVPC
Format, UVPC format files can be read directly by UVProbe
PC compatibility : Provided with UVProbe software, External control possible via USB